Blown-in insulation calculator

Enter the attic floor and the R-value you want. Get the bags of blown-in fiberglass to buy and how deep to blow it.

Your attic

Insulation level

The U.S. Department of Energy recommends R-30 to R-60 for attics, depending on climate zone.

0 for a bare attic. For old insulation, use the R-value on its label or the maker’s depth chart.

Insulation to buy22 bags
Přidejte si kalkulačku na svůj web

Kalkulačku můžete zdarma vložit na jakýkoli web. Tento kód vložte tam, kde se má zobrazit. Kalkulačka se sama aktualizuje, přizpůsobí výšku obsahu a odkazuje na úplnou stránku s vysvětlením.

Jak kalkulačku používat

  1. 01Measure the attic floor: the length and width of the area to insulate, between the outside walls.
  2. 02Pick the total R-value you want. The U.S. Department of Energy recommends R-30 to R-60 for attics, higher in colder climate zones.
  3. 03If there is old insulation, enter its R-value from its label. Leave 0 for a bare attic.
  4. 04Read the bags to buy and the depth to blow, and mark that depth on the joists before you start.

Jak výpočet funguje

Loose-fill insulation reaches its R-value only at a set weight per square foot and a set depth. The maker prints both in a coverage chart on the bag and in the data sheet, and the calculator reads that chart.

R-value to add
R wanted − R already there
Chart row
the first row at or above the R-value to add
Bags
⌈attic sq ft ÷ 1,000 × bags per 1,000 sq ft⌉
Depth
minimum thickness of that row

The numbers come from the Owens Corning AttiCat chart (27.5 lb bags). The data sheet says the stated R-value is reached only with both the bag count and at least the minimum thickness; blowing deeper with fewer bags gives a lower R-value.

The calculator never interpolates between rows. If you need R-34 more, it uses the R-38 row, because the maker does not state the bags for R-34.

Other brands and cellulose have their own charts with different bag counts and depths. If you buy another product, use its chart; the method is the same.

Příklad výpočtu

A 40 × 25 ft attic

  1. Bare attic to R-49: 1,000 sq ft ÷ 1,000 × 25 bags = 25 bags, blown at least 17 in deep.
  2. Topping up R-19 to R-49 adds R-30: 14.6 bags per 1,000 sq ft, so 15 bags at 10.75 in.
  3. In metric, 10 × 8 m = 80 m² (861 sq ft) to R-49: 22 bags, 432 mm deep.

Jak správně objednat

Mark the depth first

Staple depth rulers to the joists every few feet before blowing. The chart depth is a minimum: low spots lower the R-value of the whole attic.

Seal and baffle before you blow

Seal air leaks around lights, pipes and the attic hatch, and fit baffles at the eaves so the insulation does not block the soffit vents.

Keep clear of heat sources

Recessed lights, chimneys and flues need the clearance their makers and the local code require. Build dams around them before blowing.

Časté chyby

  • Buying by depth only. A chart row needs its bag count too; spread thinner, the same depth has less R-value.
  • Using one brand’s chart for another brand’s bags.
  • Forgetting that old insulation is often compressed or wet. Count only what is dry and at its full depth.
  • Blocking the eave vents with insulation.

Otázky a odpovědi

How many bags of blown-in insulation do I need?

Divide the attic area in square feet by 1,000 and multiply by the bags per 1,000 sq ft in the product chart for your R-value. For AttiCat at R-38 that is 19 bags per 1,000 sq ft.

How deep should blown-in insulation be for R-38?

At least 13.5 in for AttiCat fiberglass. Other products differ, so read the chart on the bag you buy.

Can I blow new insulation over old?

Yes, if the old insulation is dry and there are no moisture or pest problems. Add the R-value you still need on top.

What R-value should my attic have?

The U.S. Department of Energy recommends R-30 to R-60 for attics depending on the climate zone. Your local energy code sets the minimum.

Zdroje

  1. [1]AttiCat PINK Blown-In Fiberglass Insulation, Product Data Sheet (Pub. No. 10011273-L, May 2026). Owens Corning. Attic coverage chart: R-value, bags per 1,000 sq ft, maximum net coverage per bag, minimum weight per sq ft and minimum thickness, for R-13 to R-60; nominal bag weight 27.5 lb. The R-value is reached only with both the bag count and the minimum thickness. Ověřeno 19. listopadu 2026
  2. [2]Insulation. U.S. Department of Energy, Energy Saver. Recommended attic R-values by climate zone: uninsulated attic R30–R49 (zone 1), R49–R60 (zones 2–3), R60 (zones 4–8); with 3–4 in already there R19–R38, R38–R49, R49. Ověřeno 19. listopadu 2026
  3. [3]Climate Pro B7600 Extended Coverage Chart. Johns Manville. 30 lb nominal bag; R-30 10.8 in, 13.7 bags per 1,000 sq ft; R-38 13.4 in, 17.7 bags; R-49 16.9 in, 23.4 bags; R-60 20.2 in, 29.2 bags. Ověřeno 20. listopadu 2026
  4. [4]Stabilized for Attics Only cellulose insulation, attic card INS506LD. GreenFiber. 30 lb nominal bag; chart based on settled thickness. R-38 11.2 in initial, 10.4 in settled, 43.9 bags per 1,000 sq ft; R-49 14.3 / 13.3 in, 60.5 bags; R-60 17.3 / 16.1 in, 77.1 bags; both the bag count and the installed thickness are required. Ověřeno 20. listopadu 2026
  5. [5]Adding attic insulation (DIY guide). ENERGY STAR. Air-seal the attic first, then check insulation levels; add more if the insulation is level with or below the floor joists; look for low spots such as thin coverage along the eaves. Ověřeno 20. listopadu 2026
  6. [6]Blown Insulation for Attics: Fiberglass vs. Cellulose. Fine Homebuilding. Fluffing loose-fill is prohibited by the federal R-Value Rule; blown cellulose settles over time; check both the installed depth and the bag count against the chart. Ověřeno 20. listopadu 2026