Kort svar
A room of 450 to 550 ft² (42 to 51 m²) needs 12,000 BTU/h, which is 1 ton or 3.5 kW. A 150 to 250 ft² bedroom needs 6,000 BTU/h (1.8 kW). Add 10 % for a very sunny room, 600 BTU/h for each regular occupant above two and 4,000 BTU/h for a kitchen.
Beräkna
Effektkalkylator för luftkonditionering (BTU)
Se vilken effekt en luftkonditionering, split-AC eller värmepump behöver för rummet, i BTU, kW och kylton.
Effektkalkylator för luftkonditionering (BTU) →BTU chart by square feet and square metres
This is the sizing chart that ENERGY STAR, the US government efficiency programme, publishes for room air conditioners. It assumes a ceiling of 8 ft (2.44 m). Find the band your floor area falls into and read the capacity across.
| Area, ft² | Area, m² | BTU per hour | kW | Tons |
|---|---|---|---|---|
| 100–150 | 9.3–13.9 | 5,000 | 1.47 | 0.42 |
| 150–250 | 13.9–23.2 | 6,000 | 1.76 | 0.50 |
| 250–300 | 23.2–27.9 | 7,000 | 2.05 | 0.58 |
| 300–350 | 27.9–32.5 | 8,000 | 2.34 | 0.67 |
| 350–400 | 32.5–37.2 | 9,000 | 2.64 | 0.75 |
| 400–450 | 37.2–41.8 | 10,000 | 2.93 | 0.83 |
| 450–550 | 41.8–51.1 | 12,000 | 3.52 | 1.00 |
| 550–700 | 51.1–65.0 | 14,000 | 4.10 | 1.17 |
| 700–1,000 | 65.0–92.9 | 18,000 | 5.28 | 1.50 |
| 1,000–1,200 | 92.9–111.5 | 21,000 | 6.15 | 1.75 |
| 1,200–1,400 | 111.5–130.1 | 23,000 | 6.74 | 1.92 |
| 1,400–1,500 | 130.1–139.4 | 24,000 | 7.03 | 2.00 |
| 1,500–2,000 | 139.4–185.8 | 30,000 | 8.79 | 2.50 |
| 2,000–2,500 | 185.8–232.3 | 34,000 | 9.96 | 2.83 |
The kW column is the BTU figure divided by 3,412, and the ton column divides by 12,000, which is how the US Department of Energy defines one ton of cooling. Mini-splits sold in Europe and Asia are labelled in kW, North American units in BTU per hour; it is the same quantity.
Four corrections that change the size
The chart describes an average room. ENERGY STAR gives four adjustments, and they are worth doing, because a sunny corner bedroom and a shaded one of the same size can differ by a whole unit size.
- Heavily shaded room: take 10 % off the chart figure.
- Very sunny room: add 10 %.
- More than two people use the room regularly: add 600 BTU/h for each extra person.
- Kitchen: add 4,000 BTU/h for the heat from cooking.
Apply the sun correction to the chart value, then add the people and the kitchen. The result is the smallest unit that will keep up; choose the model rated at or just above it.
Worked example: a sunny bedroom, 12 × 14 ft
Area: 12 × 14 = 168 ft² (15.6 m²), which sits in the 150 to 250 ft² band: 6,000 BTU/h.
The room faces west with no shade, so add 10 %: 6,600 BTU/h. Two people sleep there, which the chart already includes.
Result: 6,600 BTU/h, 1.93 kW. A 6,000 BTU window unit would run flat out on hot afternoons; an 8,000 BTU unit or a 2.0 kW indoor head is the right choice.
Worked example: a kitchen of 300 ft² used by a family of four
Area: 300 ft² (27.9 m²), band 300 to 350 ft²: 8,000 BTU/h.
Kitchen: plus 4,000 BTU/h. Four people regularly there, two more than the chart assumes: plus 2 × 600 = 1,200 BTU/h.
Result: 13,200 BTU/h, which is 3.87 kW or 1.1 tons. Without the kitchen correction you would have bought an 8,000 BTU unit, and it would lose the fight every evening.
Worked example: an open-plan living area of 900 ft²
Area: 900 ft² (83.6 m²), band 700 to 1,000 ft²: 18,000 BTU/h. Large south windows, very sunny: plus 10 %, 19,800 BTU/h.
That is 5.8 kW or 1.65 tons. In practice this is often split between two indoor units on one multi-split outdoor unit, so the cold air reaches both ends of the room.
Why a bigger unit is not safer
An oversized air conditioner cools the air fast, reaches the thermostat setting and switches off before it has pulled much moisture out. The room ends up cool and clammy, and the frequent starts waste energy and wear the compressor. The Department of Energy's Building America guidance, written by the Pacific Northwest National Laboratory, warns against oversizing cooling equipment for this reason.
So round to the nearest size that covers the result, not two sizes up. If you are between sizes in a sunny climate, take the larger one; in a shaded flat, the smaller.
When the chart is not enough
The chart is meant for one room cooled by one unit. A whole house, a ducted system or a heat pump that will also heat the house needs a room-by-room load calculation: ACCA Manual J in North America, EN 12831 for the heating side in Europe. Any installer quoting a central system should do one and show it to you.
Rooms with ceilings much higher than 8 ft, attic rooms under an uninsulated roof and conservatories with glass roofs also fall outside the chart. Use it as a lower limit there and ask for a calculation.
Frågor
How many BTU do I need for 1,000 square feet?
Exactly 1,000 ft² starts the 1,000 to 1,200 ft² band of the ENERGY STAR chart: 21,000 BTU/h, about 6.2 kW or 1.75 tons, before corrections for sun, people and a kitchen.
What size AC do I need for a 20 m² room?
20 m² is 215 ft², which the chart puts at 6,000 BTU/h, or 1.76 kW. Choose a 2.0 kW or 2.5 kW unit if the room is very sunny.
How many square feet does a 1 ton AC cool?
One ton is 12,000 BTU/h, which the ENERGY STAR chart gives for 450 to 550 ft² (42 to 51 m²) with an 8 ft ceiling.
Is 5,000 BTU enough for a bedroom?
Only for a small one: the chart gives 5,000 BTU/h for 100 to 150 ft² (9.3 to 13.9 m²). A typical 12 × 12 ft bedroom of 144 ft² is at the top of that band, so a sunny one needs 6,000 BTU.
How do I convert BTU to kW?
Divide BTU per hour by 3,412. 12,000 BTU/h is 3.52 kW; 9,000 BTU/h is 2.64 kW.
Beräkna
Effektkalkylator för luftkonditionering (BTU)
Se vilken effekt en luftkonditionering, split-AC eller värmepump behöver för rummet, i BTU, kW och kylton.
Effektkalkylator för luftkonditionering (BTU) →Källor
- [1]Room Air Conditioners: find the correct cooling capacity. ENERGY STAR (U.S. EPA and DOE). Capacity by area cooled (based on an 8-foot ceiling), 100 to 2,500 ft²: 5,000 to 34,000 Btu/h. Adjustments: heavily shaded −10 %, very sunny +10 %, +600 Btu/h for each person above two who regularly occupies the room, +4,000 Btu/h in a kitchen. Kontrollerat 18 november 2026
- [2]Building America Solution Center: Air Conditioning. Pacific Northwest National Laboratory (U.S. DOE). One ton equals 12,000 Btu/h of cooling capacity. Cooling systems should not be oversized; the whole-house load is calculated with ACCA Manual J. Kontrollerat 18 november 2026