Hoppa till innehållet
Yardox

Air purifier size

Enter the room size and how clean you want the air: see the smoke CADR an air purifier needs, from AHAM’s air changes per hour, and whether the unit you are looking at is big enough.

Room

m
m
m

The level behind the suggested room size on the AHAM Verifide seal: 80 % fewer particles.

Check a unit

m³/h

The smoke CADR from the AHAM label or the box. Leave empty to see only what the room needs.

2.23.64.867.5Add a unit’s smoke CADR to see where it falls
Air changes per hour from the purifier. Dashed lines are AHAM’s targets, the solid line is the one you picked.
Smoke CADR needed240 m³/h
Lägg till kalkylatorn på din webbplats

Det är gratis för alla webbplatser att använda kalkylatorn, klistra bara in koden där den ska visas. Kalkylatorn uppdateras automatiskt, anpassar höjden till innehållet och länkar till hela sidan med förklaringar.

Så använder du kalkylatorn

  1. 01Enter the length, width and ceiling height of the room.
  2. 02Pick how clean you want the air. The standard level is the one AHAM uses for the room size on its seal; pick wildfire smoke if smoke gets in from outside.
  3. 03Read the smoke CADR you need. To check a model, enter its smoke CADR: you see the air changes it gives and how many units the room takes.

Så räknar vi

A 16 × 12 ft bedroom with an 8 ft ceiling needs an air purifier with a smoke CADR of about 123 cfm at AHAM’s standard level. CADR, the clean air delivery rate, is the flow of filtered air a unit delivers; divided by the room volume it gives the equivalent air changes per hour (eACH).

Room volume
length × width × ceiling height
Smoke CADR needed
eACH × volume ÷ 60 (cfm from cu ft); eACH × volume (m³/h from m³)
Air changes from a unit
eACH = smoke CADR × 60 ÷ volume

The targets come from AHAM’s white paper “Consumer Room Air Cleaners and Equivalent Air Changes per Hour” (January 2026). At 4.8 eACH a purifier removes about 80 % of particles; this is the level behind AHAM’s suggested room size, 1.55 × smoke CADR in square feet for an 8 ft ceiling. So a unit with a 100 cfm smoke CADR suits a room of 155 sq ft.

The paper lists other levels: 2.2 eACH only for a home built tight to ASHRAE 62.2 with no smoke event; 3.6 and 6.0 eACH from ASHRAE 241 at 30 and 50 cfm per person; and 7.5 eACH for wildfire smoke, where the room size in square feet equals the smoke CADR in cfm.

The calculator uses the room volume, so a higher ceiling raises the CADR you need. The 1.55 rule on the label assumes an 8 ft ceiling.

Räkneexempel

A 16 × 12 ft (4.9 × 3.7 m) bedroom, 8 ft (2.4 m) ceiling

  1. Volume: 16 × 12 × 8 = 1,536 cu ft.
  2. Standard level: 4.8 × 1,536 ÷ 60 = 122.9, so a smoke CADR of at least 123 cfm.
  3. A unit rated 100 cfm gives 100 × 60 ÷ 1,536 = 3.9 eACH: short of 4.8, so pick a larger one or use two.
  4. Metric: a 5 × 4 m room with a 2.5 m ceiling is 50 m³; 4.8 × 50 = 240 m³/h, about 141 cfm.

Tips inför beställningen

Use the smoke figure

AHAM bases its room size on the smoke CADR. Enter that number from the label.

Smoke season

For wildfire smoke AHAM’s paper goes up to 7.5 eACH: the floor area in square feet should not exceed the smoke CADR in cfm. A 200 cfm unit suits 200 sq ft (19 m²) with an 8 ft ceiling.

Tall rooms

The label’s room size is for an 8 ft (2.4 m) ceiling. With a 10 ft (3 m) ceiling the same unit covers about a fifth less floor.

Vanliga misstag

  • Buying by the room size on the box when the ceiling is higher than 8 ft: the room has more air than the label assumes.
  • Using the minimum 2.2 eACH level in an ordinary home: AHAM allows it only for a tight home built to ASHRAE 62.2, with no smoke or infection risk.
  • Comparing CADR in cfm with a figure in m³/h: 1 cfm is 1.7 m³/h.

Frågor

What size air purifier do I need?

Multiply the room volume by 4.8 air changes and divide by 60. A 16 × 12 ft room with an 8 ft ceiling needs a smoke CADR of about 123 cfm. With an 8 ft ceiling you can also divide the floor area by 1.55, AHAM’s label rule: 192 ÷ 1.55 = 124 cfm, a hair above the exact 123.

What CADR do I need for 300 sq ft?

192 cfm at AHAM’s standard level with an 8 ft ceiling (4.8 × 2,400 cu ft ÷ 60); AHAM’s label rule, 300 ÷ 1.55, gives about 194. For wildfire smoke you need 300 cfm. Metric: 28 m² with a 2.4 m ceiling is 67 m³, so 4.8 × 67 = 322 m³/h.

How many air changes per hour should an air purifier give?

AHAM’s standard is 4.8, about 80 % fewer particles. Its paper also lists 6.0 and 7.5 for higher risk, and 2.2 as a floor for tight homes only.

What is CADR?

The clean air delivery rate: how much filtered air a purifier delivers, in cubic feet per minute (cfm) or cubic metres per hour (m³/h). AHAM bases room size on the smoke figure.

Källor

  1. [1]Consumer Room Air Cleaners and Equivalent Air Changes per Hour (white paper, January 2026). Association of Home Appliance Manufacturers (AHAM). eACH = smoke CADR × 60 ÷ room volume (ft³); suggested room size = 1.55 × smoke CADR for an 8 ft ceiling (4.8 eACH, AHAM AC-1, 80 % reduction); Table 2 targets: 2.2 eACH (ASHRAE 62.2 tighter home), 3.6 (ASHRAE 241, 30 cfm/person, 75 %), 4.8 (AC-1, 80 %), 6.0 (ASHRAE 241, 50 cfm/person, 83 %), 7.5 (wildfire smoke, room size = smoke CADR, 86 %). Kontrollerat 24 november 2026

Formler och källor kontrollerades senast 24 november 2026. Så räknar vi