Kort svar
A bedroom needs about 5 footcandles (54 lux), a kitchen worktop 50 footcandles (538 lux). In a 12 × 12 ft room with light walls that means roughly 9 lamp lumens per square foot for a bedroom and 93 for kitchen work: the lamp lumens are about 1.9 times the footcandle target.
Beräkna
Kalkylator för belysning
Se hur många infällda spotlights eller taklampor rummet behöver och hur tätt de ska sitta.
Kalkylator för belysning →Footcandles, lux and lumens
One footcandle is one lumen falling on one square foot. One lux is one lumen on one square metre, so 1 footcandle equals 10.76 lux. These describe the light that arrives on a surface.
A lumen figure on a bulb or downlight is the light the lamp sends out. Some of it hits the walls and ceiling and is partly absorbed, and LEDs and fittings lose output with age and dust. Lighting designers call the share that arrives the utilisation factor and the ageing allowance the maintenance factor. Both are below 1, which is why you divide by them.
Recommended light levels by room
There is no binding standard for homes. The levels below come from the IES Lighting Handbook as published by the US Department of Energy, and, where it gives a figure, from licht.de, the German lighting industry association. The last two columns turn each target into lamp lumens for one typical room: 12 × 12 ft (3.66 × 3.66 m), 8 ft ceiling, light walls and ceiling, light measured at table height, LED fittings.
| Room | Target | Source | Lamp lm per ft² (per m²) | Lamp lm for the room |
|---|---|---|---|---|
| Living room, general | 3 fc (32 lx) | IES | 5.6 (60) | 810 |
| Hallway | 3 fc (32 lx) | IES | 5.6 (60) | 810 |
| Bedroom | 5 fc (54 lx) | IES | 9.3 (101) | 1,350 |
| Stairs | 5 fc (54 lx) | IES | 9.3 (101) | 1,350 |
| Garage | 5 fc (54 lx) | IES | 9.3 (101) | 1,350 |
| Family room | 10 fc (108 lx) | IES | 18.7 (201) | 2,690 |
| Dining room | 10 fc (108 lx) | IES | 18.7 (201) | 2,690 |
| Laundry | 20 fc (215 lx) | IES | 37.4 (402) | 5,380 |
| Bathroom | 300 lx (27.9 fc) | licht.de | 52 (560) | 7,500 |
| Vanity mirror | 30 fc (323 lx) | IES | 56 (603) | 8,070 |
| Kitchen | 500 lx (46.5 fc) | licht.de | 87 (934) | 12,500 |
| Home office desk | 500 lx (46.5 fc) | licht.de | 87 (934) | 12,500 |
| Kitchen counter, food preparation | 50 fc (538 lx) | IES | 93 (1,005) | 13,450 |
The two sources differ in approach. The IES gives a low general level for most rooms and a high level only where you work, such as a counter or a mirror. licht.de gives one level for the whole kitchen or bathroom. For a kitchen, the IES way is usually cheaper and nicer to live with: modest ceiling light plus strong light over the worktop.
Where the factor of 1.9 comes from
For the table room, the lights hang 5.5 ft above a table 2.5 ft high. The room index, which describes how much of the light lands on the walls, is 144 / ((12 + 12) × 5.5) = 1.09.
The published utilisation table of a Philips recessed LED downlight gives 0.64 at an index of 1 and 0.72 at 1.25 for light surfaces (ceiling 70 %, walls 50 %, floor 20 % reflectance). Between them: 0.67. A worked example by the luminaire maker Fagerhult uses a maintenance factor of 0.8 for LEDs in a clean room.
Lamp lumens = target × area / (0.67 × 0.8), so each footcandle on the table needs 1.87 lamp lumens per square foot. A smaller or taller room, or dark walls, pushes the factor up: with medium surfaces (50/30/10) the same room needs about 2.2 times the target.
Worked example: a kitchen of 5 × 4 m
Ceiling 2.6 m, worktop 0.75 m high, target 500 lux (licht.de), light surfaces.
- Height of the lights above the worktop: 2.6 − 0.75 = 1.85 m.
- Room index: 20 / ((5 + 4) × 1.85) = 1.20, which gives a utilisation factor of 0.704 from the same table.
- Lamp lumens: 500 × 20 / (0.704 × 0.8) = 17,760 lm.
- With 600 lm downlights that is 30 lights. With 1,200 lm downlights, 15 would be bright enough, but they must also be close enough together for even light.
Thirty downlights is a lot of holes. The usual answer is the IES approach: a few downlights for 5 to 10 footcandles of general light, plus LED strips under the wall cupboards that put 50 footcandles exactly on the worktop.
Spacing downlights
Enough lumens in the wrong places still leaves dark corners. Kichler recommends a gap of half the ceiling height between downlights, no more than 6 ft, and at least 2 ft from the walls. In a room with an 8 ft ceiling that is a 4 ft grid; in a 2.5 m room, 1.25 m. If the spacing rule asks for more lights than the brightness does, use lower-output lights or put them on a dimmer.
Mistakes that leave a room too dark or too harsh
Most lighting complaints come from four habits carried over from incandescent bulbs.
- Choosing bulbs by watts. LEDs of the same wattage can give very different lumens; compare the lumen figure.
- Using the target level as the lumen figure. The lamps must send out about twice the target, more in small or dark rooms.
- One bright level everywhere. A hallway at kitchen-counter level is glaring and wastes power.
- Forgetting dark walls and ceilings. A dark room needs noticeably more lamp light for the same result.
Frågor
How many lumens per square foot do I need?
It depends on the room: about 5.6 lamp lumens per ft² for a living room or hallway, 9 for a bedroom, 19 for a dining room and 87 to 93 for kitchen work, in a 12 × 12 ft room with light walls.
How many lumens for a bedroom?
The IES recommends 5 footcandles. In a 12 × 12 ft bedroom with light walls that takes about 1,350 lamp lumens, for example two 700 lm lamps.
How many lumens does a kitchen need?
licht.de recommends 500 lux. A 5 × 4 m kitchen with a 2.6 m ceiling needs about 17,760 lamp lumens for that level everywhere; with the IES approach, less general light plus strong under-cabinet light on the worktop.
How many lux is a footcandle?
10.76 lux. One footcandle is one lumen per square foot, one lux one lumen per square metre.
How far apart should recessed lights be?
Half the ceiling height, at most 6 ft, and at least 2 ft from the walls (Kichler). In an 8 ft room, 4 ft apart.
Beräkna
Kalkylator för belysning
Se hur många infällda spotlights eller taklampor rummet behöver och hur tätt de ska sitta.
Kalkylator för belysning →Källor
- [1]Strategy Guideline: High Performance Residential Lighting (J. Holton, IBACOS, February 2012), Table 1. U.S. Department of Energy, Building America. Recommended horizontal illuminance for homes after the IES Lighting Handbook, 10th ed., Table 33.2 (occupants 25 to 65): living room 3 fc, family room 10 fc, bedroom 5 fc, informal dining 10 fc, hallway 3 fc, stairs 5 fc, laundry 20 fc, garage 5 fc, walk-in closet 30 fc, kitchen prep counter 50 fc, bath vanity 30 fc, home office 20 fc. Kontrollerat 18 november 2026
- [2]licht.wissen 14: Licht für Wohnräume. licht.de (Fördergemeinschaft Gutes Licht, ZVEI). Kitchen 500 lx; bathroom general lighting 300 lx; reading, homework and home office 500 lx. Kontrollerat 18 november 2026
- [3]General uniform lighting: DN027B G3 LED6 NW 6W D90 recessed downlight, utilisation factors. Signify (Philips Lighting). Utilisation factors of a ceiling-mounted LED downlight by room index k = 0.60 to 5.00, for reflectances ceiling/walls/working plane 0.70/0.50/0.20, 0.50/0.30/0.10 and 0.30/0.10/0.10. Kontrollerat 18 november 2026
- [4]Lighting Design Guide (CLS-CC2454, November 2013). Eaton's Cooper Lighting and Safety. Lumen method E = F × N × MF × UF / A and room index K = L × W / ((L + W) × Hm), Hm = height of the luminaire above the working plane. Kontrollerat 18 november 2026
- [5]Planning and calculation tips: maintenance factor. Fagerhult. Maintenance factor MF = LLMF × LSF × LMF × RSMF; worked example for an LED luminaire in a clean room, cleaned every 3 years: 0.9 × 1 × 0.94 × 0.95 = 0.8. Kontrollerat 18 november 2026
- [6]Downlight and recessed lighting placement tips. Kichler Lighting. Spacing between downlights = ceiling height / 2, but no more than 6 ft apart; start no less than 2 ft from the walls. Kontrollerat 18 november 2026