Перейти до вмісту
Yardox

Plywood and OSB sheet calculator

Enter your walls, floors or roof and the sheet size. Get how many sheets of plywood or OSB to buy, from the real layout.

Surfaces to sheathe

01Surface 1

For example 2 for both slopes of a gable roof.

Doors and windows are cut out of whole sheets, so leave them in.

Sheets

%

For mistakes and damaged sheets. The layout already counts the cut pieces.

Sheets to buy20 sheets of 1.25 × 2.5 m
Додайте цей калькулятор на свій сайт

Калькулятор безкоштовний для будь-якого сайту. Вставте код туди, де має з'явитися калькулятор. Калькулятор оновлюється автоматично, підлаштовує висоту під вміст і містить посилання на повну сторінку з поясненнями.

Як користуватися

  1. 01Add each wall, floor or roof slope to sheathe, with how many are alike.
  2. 02For a floor, enter the length across the joists and the width along them. For a roof, enter the length along the ridge and the slope length from eave to ridge.
  3. 03Enter the sheet size, such as 4 × 8 ft.
  4. 04Add a spare if you want one, and read the sheets to buy.

Як виконується розрахунок

The calculator lays each surface out sheet by sheet, as you would on site, instead of dividing the area by the sheet area.

Whole sheets
⌊length ÷ sheet⌋ × ⌊height ÷ sheet⌋
End strips
several from one sheet when they fit
To buy
⌈sheets × (1 + spare)⌉

APA, the engineered wood association, says to install structural panels with the long dimension across the supports and continuous over two or more spans. So on floors and roofs the long side runs across the joists or rafters. Walls are laid whichever way takes fewer sheets, standing up on a tie.

Narrow strips at the end of each row and the top of each column are cut from shared sheets when two or more fit in one. Doors and windows are left in, because sheets are hung whole and the openings cut out afterwards.

APA recommends a 1/8 in gap at panel edges and ends unless the panel maker says otherwise; it does not change the sheet count.

Приклад розрахунку

Four 20 × 8 ft walls

  1. Each wall: five 4 × 8 sheets standing up, 20 sheets in all.
  2. A gable roof, two slopes of 30 × 14 ft: 15 sheets a slope, 30 in all, 33 with 10 % spare.
  3. In metric, four 6 × 2.5 m walls with 1.25 × 2.5 m sheets: 5 a wall, 20 in all.

Як правильно замовити

Stagger the joints

On floors and roofs, stagger the end joints of neighbouring rows.

Check the span rating

The stamp on each panel gives its span rating. It must suit the joist or rafter spacing.

Order a few extra

A spare sheet or two covers a mis-cut or a damaged corner without another trip to the store.

Поширені помилки

  • Dividing the area by 32 sq ft and forgetting the offcuts at the ends of the rows.
  • Running floor sheets along the joists instead of across them.
  • Subtracting windows and doors from walls that are sheathed with whole sheets.

Запитання

How many sheets of plywood do I need?

Lay the surface out in sheets: whole sheets along and up, then the strips at the ends. A 12 × 8 ft wall takes three 4 × 8 sheets; a 10 × 8 ft wall also takes three, because the two 2 × 4 ft end strips come from one sheet.

How many sheets of OSB for a roof?

Measure each slope along the ridge and from eave to ridge, and lay it out with the long side along the ridge. A 30 × 14 ft slope takes 15 sheets of 4 × 8.

How many square feet is a sheet of plywood?

A 4 × 8 ft sheet is 32 sq ft; a 1.25 × 2.5 m sheet is 3.125 m².

Джерела

  1. [1]Engineered Wood Construction Guide: Roof Construction (Form E30W, revised February 2016). APA – The Engineered Wood Association. Structural panels 4 × 8 ft; panels continuous over two or more spans with the long dimension (strength axis) across supports; 1/8 in space at all edge and end joints unless the panel maker says otherwise. Table 34 (roof sheathing, strength axis across supports), span rating: minimum thickness, max span with / without edge support: 24/0 3/8 in 24/19.2 in; 24/16 7/16 in 24/24 in; 32/16 15/32 in 32/28 in; 40/20 19/32 in 40/32 in; 48/24 23/32 in 48/36 in; 60/32 7/8 in 60/40 in. Edge support: tongue-and-groove edges, panel edge clips (one midway between supports, two equally spaced when supports are 48 in o.c. or more) or lumber blocking. Footnote: 24/0 unsupported span 19.2 in for 3/8 and 7/16 category panels, 24 in for 15/32 and 1/2. Table assumes 10 psf dead load; tile roofs lower the allowable live load; heavy concentrated loads may need more. Перевірено 19 листопада 2026 р.
  2. [2]Engineered Wood Construction Guide: Floor Construction (Form E30). APA – The Engineered Wood Association. Table 16, APA Rated Sheathing as subfloor, span rating: thickness, max joist spacing: 24/16 7/16 in 16 in; 32/16 15/32 or 1/2 in 16 in; 40/20 19/32 or 5/8 in 19.2 in; 48/24 23/32 or 3/4 in 24 in; 60/32 7/8 in 32 in; 6d common nails for 24/16, 8d for the others (6d allowed for 1/2 in or less), 6 in at edges, 12 in in the field. Sturd-I-Floor is designed for single-layer floor construction beneath carpet and pad. Table 16 footnote: see Table 18 for ceramic tile. Table 14, APA Rated Sturd-I-Floor: 16 oc 19/32 or 5/8 in; 20 oc 19/32 or 5/8 in; 24 oc 23/32 or 3/4 in; 32 oc 7/8 in; 48 oc 1 3/32 or 1 1/8 in. 1/8 in gap at panel edges and ends, also at tongue-and-groove edges. Перевірено 20 листопада 2026 р.
  3. [3]PS 2-18 Performance Standard for Wood Structural Panels, Table 1. NIST / APA. Performance categories: 23/32 PERF CAT panels measure 0.688–0.750 in (17.46–19.05 mm); 3/4 PERF CAT 0.719–0.781 in (18.26–19.84 mm); panels are sold by performance category, not exact thickness. Перевірено 20 листопада 2026 р.

Формули та джерела востаннє перевірено 20 листопада 2026 р.. Як ми рахуємо