Коротка відповідь
For a tank, add up the hot water your household uses in its busiest hour: a family of four with three showers, a shave and dishes by hand needs about 65 gallons (246 L), so buy a heater with a first hour rating of at least 65. For a tankless heater, one shower plus one tap is 3.25 gpm (12.3 L/min) and needs about 114,000 BTU/h (33 kW) with 50 °F inlet water.
Розрахувати
Калькулятор підбору водонагрівача
Скільки гарячої води бойлер має подати за першу годину або які витрата води й потужність потрібні для проточного водонагрівача у вашому домі.
Калькулятор підбору водонагрівача →Hot water per use
The US Department of Energy sizes a storage or heat pump water heater on peak hour demand: the hot water used in the busiest hour of a normal day. These are the amounts its worksheet counts for each use.
| Use | Gallons | Litres |
|---|---|---|
| Shower | 20 | 76 |
| Shaving | 2 | 8 |
| Washing dishes by hand or food prep | 3 | 11 |
| Automatic dishwasher | 7 | 26 |
| Top-loading clothes washer | 25 | 95 |
| Front-loading clothes washer | 15 | 57 |
Think about when your household actually overlaps. For most families it is the morning, when everyone showers before work and school. For others it is the evening, when the washer and dishwasher run while someone is in the shower.
Peak hour demand for typical households
Add the uses that happen in the same hour. The total is the minimum first hour rating (FHR) to look for on the yellow EnergyGuide label or in the data sheet.
| Household and busiest hour | Sum | FHR at least |
|---|---|---|
| One person: shower and dishwasher | 20 + 7 | 27 gal (102 L) |
| Couple: two showers, a shave, dishes by hand | 40 + 2 + 3 | 45 gal (170 L) |
| Family of four: three showers, a shave, dishes by hand | 60 + 2 + 3 | 65 gal (246 L) |
| Family of five, evening: three showers, dishwasher, top-loading washer | 60 + 7 + 25 | 92 gal (348 L) |
The last row shows how much one appliance matters: swap the top-loader for a front-loader and the same evening needs 82 gallons, not 92. Moving the laundry to another hour takes 25 gallons off the peak entirely.
First hour rating is not tank size
The first hour rating is how much hot water the heater delivers in one hour starting with a full tank. It includes what the burner, element or heat pump heats during that hour, so two heaters with the same tank can have different ratings: the faster one reheats, the more it delivers.
That is why the DOE tells you to compare the rating with your peak demand and not the gallons printed on the side. Two 50-gallon tanks can differ a lot.
Tankless: flow and temperature rise
A tankless heater has no store, so it must heat the water as fast as you draw it. Its size is a flow rate at a temperature rise. The DOE method: add the flow of the outlets you use at the same time, then find the rise from your incoming water to about 120 °F (49 °C). If you do not know your inlet temperature, use 50 °F (10 °C); the rise is then 70 °F (39 °C).
The DOE uses 2.5 gallons per minute for a shower and 0.75 gpm for a faucet as examples. Heating water takes about 500 BTU per hour for each gpm and each degree Fahrenheit of rise, from the weight of water (62.4 lb per cubic foot at 50 °F, U.S. Geological Survey) and one BTU per pound per degree.
| Used at once | Flow | Power |
|---|---|---|
| One shower | 2.5 gpm (9.5 L/min) | 87,600 BTU/h (25.7 kW) |
| Shower and a kitchen tap | 3.25 gpm (12.3 L/min) | 114,000 BTU/h (33.4 kW) |
| Two showers | 5 gpm (18.9 L/min) | 175,000 BTU/h (51.3 kW) |
The DOE notes that gas tankless units reach a 70 °F rise at about 5 gpm, electric ones at about 2 gpm. In practice that means a whole-house electric tankless heater suits one shower at a time; a family that runs two showers together needs gas, two units or a tank.
Worked example: family of four, morning rush
Between 6:30 and 7:30 three people shower, one shaves and breakfast dishes are washed by hand: 60 + 2 + 3 = 65 gallons.
Tank: look for a first hour rating of at least 65 gallons (246 L) on the EnergyGuide label or data sheet. Compare models by that rating, not by tank size.
Tankless: the showers are one after another, but someone runs the kitchen tap during a shower, so the peak flow is 3.25 gpm. With 50 °F inlet water that needs about 114,000 BTU/h, which is a gas unit; an electric one would need over 33 kW.
Mistakes that leave you with cold showers
Undersized water heaters almost always come from one of these four shortcuts.
- Buying by tank volume and ignoring the first hour rating.
- Counting average daily use instead of the busiest hour.
- Sizing a tankless heater for the summer inlet temperature. In winter the incoming water is colder and the rise larger.
- Expecting an electric tankless heater on a normal household supply to serve two showers at once.
Запитання
What size water heater for a family of 4?
Count their busiest hour. Three showers, a shave and dishes by hand come to 65 gallons (246 L), so choose a first hour rating of at least 65 gallons.
Is a 40 gallon water heater enough for 4 people?
It is if its first hour rating covers your busiest hour, about 65 gallons for three showers, a shave and dishes. The tank size alone does not tell you; read the first hour rating on the label.
How many gallons of hot water does a shower use?
The DOE worksheet counts 20 gallons (76 L) per shower.
What size tankless water heater do I need for a 3 bathroom house?
Size it for the showers that run at the same time, not the number of bathrooms. Two showers at 2.5 gpm with a 70 °F rise need about 175,000 BTU/h (51 kW), which is gas territory.
What temperature rise should I use?
The difference between your incoming water and about 120 °F (49 °C). Without a measurement, the DOE suggests 50 °F (10 °C) incoming water, a 70 °F (39 °C) rise.
Розрахувати
Калькулятор підбору водонагрівача
Скільки гарячої води бойлер має подати за першу годину або які витрата води й потужність потрібні для проточного водонагрівача у вашому домі.
Калькулятор підбору водонагрівача →Джерела
- [1]Sizing a New Water Heater. U.S. Department of Energy, Energy Saver. Storage and heat pump water heaters: choose a first hour rating at least equal to the peak hour demand. Gallons per use: shower 20, shaving 2, hand dishwashing or food prep 3, automatic dishwasher 7, top-loading clothes washer 25, front-loading (H-axis) 15. Tankless: add the flow rates of devices used at once (example 0.75 gpm faucet, 2.5 gpm shower); incoming water 50 °F (10 °C) unless known; 120 °F (49 °C) for most uses; gas units reach a 70 °F rise at 5 gpm, electric at 2 gpm. Перевірено 18 листопада 2026 р.
- [2]Water Density (Water Science School). U.S. Geological Survey. Water at 50 °F (10 °C) weighs 62.408 lb/ft³ (0.99975 g/cm³); with 1 Btu per lb per °F this gives the heat to warm a flow of water. Перевірено 18 листопада 2026 р.