Short answer
Divide the wall into columns the width of a sheet and count how many sheets stack in each column. A 4.0 × 2.6 m partition boarded on both sides with 1250 × 2600 mm sheets takes 8 sheets and 264 screws. A 12 × 8 ft wall with 4 × 8 ft sheets takes 3 sheets and 84 screws.
Calculate it
Drywall calculator
Walls and ceilings: sheets, framing, screws, tape and compound.
Drywall calculator →Counting sheets for a wall
Stand the sheets upright and count columns along the wall: columns = wall length divided by sheet width, rounded up. Then count how many sheet lengths fit in the wall height. If the wall is taller than one sheet, the strip on top is cut from another sheet, and one sheet can often give several strips. Multiply by the number of layers and by the number of sides you board.
An opening only saves the sheets that it swallows whole. A door narrower than one sheet saves none, because you still cut around it. The sources used for this page give no waste percentage for sheets, so the count comes from the layout rather than from an allowance.
Worked example, metric: a 4.0 × 2.6 m partition
Sheets 1250 × 2600 mm (an example size, use the one you buy), CW studs at 625 mm, boarded on both sides with one 12.5 mm layer.
- Columns: 4.0 / 1.25 = 3.2, so 4. The wall is 2.6 m high, one sheet, so 4 sheets per side.
- Both sides: 8 sheets.
- Studs: 4.0 / 0.625 = 6.4, so 7 plus one for the end, 8 studs.
- Screws: 11 fixing lines (8 studs plus one extra for each of the 3 vertical joints, where both sheet edges are screwed to the same stud). Each line is 2.6 m high at 250 mm: 11 + 1 = 12 screws, so 132 per side and 264 in total.
Worked example, imperial: a 12 × 8 ft wall
Sheets 4 × 8 ft (an example size), studs at 16 in, one side, one layer.
- Columns: 12 / 4 = 3. Wall height 8 ft is one sheet: 3 sheets.
- Studs: 144 in / 16 = 9, plus 1 for the end, 10 studs.
- Screws: 12 fixing lines (10 studs plus 2 extra at the joints), each 96 in high at 16 in spacing: 96 / 16 = 6, plus 1, so 7 screws per line. 12 × 7 = 84 screws.
Stud spacing and sheet width
Sheet edges must land on a stud, so the stud spacing has to divide the sheet width. Knauf specifies 1250 mm wide boards on studs at 625 mm centres, which puts every sheet edge and the middle of the sheet on a stud. In inches, a 48 in sheet works with 16 in studs (three spaces) or 24 in studs (two).
Knauf lists 12.5 mm as the standard board thickness per layer, with TN 3.5 × 25 screws for a single layer and 3.5 × 25 plus 3.5 × 35 for two layers.
Screw spacing on walls
The maximum spacing along a stud depends on the system and the number of layers.
| Source | Framing | Spacing |
|---|---|---|
| Knauf W11, single layer | CW studs, vertical 1250 mm boards | 250 mm |
| Knauf W11, double layer | CW studs, vertical 1250 mm boards | first layer 750 mm, second layer 250 mm |
| USG, Gypsum Association GA-216 | framing 16 in on centre | 16 in |
| USG, Gypsum Association GA-216 | framing 24 in on centre | 12 in |
Knauf keeps screws 10 mm from a paper-covered edge and 15 mm from a cut edge. The Gypsum Association article adds at least 3/8 in from the edge of the board and says to start in the middle of the board and work outward, so the edges are fixed last.
Spacing sets the screw count. At 250 mm a metre of stud takes 4 screws; at 16 in a foot takes 0.75, and at 12 in exactly 1.
Ceilings
On a ceiling the boards go across the framing, and the screws are closer together because the board hangs from them. Knauf specifies CD profiles at 500 mm at most for boards up to 15 mm, and Danogips confirms profiles at 500 mm at most with the boards laid crosswise. For one 12.5 mm layer Knauf gives a screw every 170 mm. With two layers the first may go up to 500 mm and the second takes 170 mm. Danogips agrees on 170 mm for the outer layer.
In the US, USG gives screws 12 in apart or closer on framing 16 in on centre or closer, and the Gypsum Association article gives 12 in for a single layer on framing at 16 or 24 in.
Knauf asks for end joints in the ceiling to be offset by at least 400 mm. For a 4 × 3.5 m ceiling with 1250 × 2000 mm boards laid across profiles at 500 mm, the count is 3 columns of 2 boards, so 6 boards and 9 profile lines. At 170 mm, a metre of profile takes about 6 screws, against 4 on a wall.
Joint compound
Knauf Uniflott takes about 0.25 kg/m² for one side of a single 12.5 mm layer and 0.4 kg/m² for two layers; for a wall boarded on both sides, 0.5 and 0.8 kg/m². For the partition above, 4.0 × 2.6 = 10.4 m² per side, so 10.4 × 0.25 × 2 = 5.2 kg. USG says about two 4.5 gal pails of ready-mixed compound finish 1000 sq ft of wallboard.
Questions
How many sheets of drywall for a 12 × 12 ft room?
Four walls of 12 × 8 ft with 4 × 8 ft sheets need 3 sheets each, so 12. Subtract only the sheets a door or window swallows whole, and add the ceiling separately.
How far apart should drywall screws be?
USG and the Gypsum Association give 16 in on walls with 16 in framing and 12 in with 24 in framing, and 12 in on ceilings. Knauf gives 250 mm on walls for a single layer and 170 mm on ceilings.
How many screws per sheet?
It depends on the stud spacing and sheet length. Count stud lines times screws per line, as in the examples above. On 16 in studs a 4 × 8 ft sheet crosses 4 stud lines of 7 screws each, 28 in all, although the edge lines are shared with the neighbouring sheet.
What is the stud spacing for 1250 mm boards?
Knauf specifies 625 mm, so that the edges and the centre of each sheet land on a stud. For ceilings with 12.5 mm boards, CD profiles at 500 mm.
Does the same apply to plasterboard from other makers?
The spacing rules here come from Knauf, Danogips, USG and the Gypsum Association. For another board, follow the data sheet of that board.
Calculate it
Drywall calculator
Walls and ceilings: sheets, framing, screws, tape and compound.
Drywall calculator →Sources
- [1]Detailblatt W11.de Knauf Metallständerwände (08/2015; stud spacings re-checked in edition 01/2024). Knauf Gips KG. Screw spacing on CW studs: single layer ≤ 250 mm; double layer: first layer ≤ 750 mm, second layer ≤ 250 mm (vertical boards, 1250 mm wide). Stud spacing 625 mm for 1250 mm boards.. Checked November 5, 2026
- [2]Knauf Uniflott, Produkt-Datenblatt K4604_DSP.de (03/2025). Knauf Gips KG. Joint filler about 0.25 kg/m² for one side of 12.5 mm boards (Vorsatzschale) and 0.4 kg/m² for two layers of 12.5 mm; 0.5 and 0.8 kg/m² for a wall boarded on both sides. Bags of 5 and 25 kg.. Checked November 5, 2026
- [3]USG FAQ: fastener spacing for gypsum panels. USG. Walls: screws 16 in apart on framing 16 in on center, 12 in apart on framing 24 in on center. Ceilings: screws 12 in apart or closer on framing 16 in on center or closer.. Checked November 5, 2026
- [4]All Things Gypsum: Attachment of Gypsum Board (Walls & Ceilings, 2006). Michael Gardner, Gypsum Association. Confirms the GA-216 wall screw spacing: 16 in on 16 in framing, 12 in on 24 in framing, for wood and steel studs. Ceilings: framing typically 16 or 24 in on center; single-layer screw attachment 12 in apart.. Checked November 5, 2026
- [5]USG FAQ: coverage of Sheetrock UltraLightweight All Purpose Joint Compound. USG. About two 4.5 gal pails of ready-mixed compound to finish 1000 sq ft of wallboard.. Checked November 5, 2026
- [6]Tehnični list D11: Knauf stropni sistemi (03/2006). Knauf (Slovenia). Ceiling boards are fixed across the CD profiles. One layer of 12.5 mm: screws every 170 mm; two layers: first layer up to 500 mm, second layer 170 mm. Profile spacing 500 mm for boards up to 15 mm.. Checked November 6, 2026
- [7]DANO System-Index, D 90-12 suspended ceiling (technical status 04/2026). Danogips GmbH & Co. KG. Confirms CD 60/27 profiles at ≤ 500 mm with boards laid crosswise, and outer-layer screws at ≤ 170 mm.. Checked November 6, 2026