Skip to content
Yardox

Ramp calculator

Plan a wheelchair or step-free ramp: how long it must be for your height, where landings go and how wide it should be.

Your ramp

Length, runs and landings after the accessibility rule you choose: the US ADA Standards, Approved Document M (England and Wales) or DIN 18040 (Germany).

Side view of the ramp with runs and landings, unfolded into a straight line28 ft 0 in1 ft 6 in

Height and rule

in

From the ground at the foot to the floor at the door, measured vertically.

1:12 at most, a landing after every 30 in of rise.

Ramp length18 ft 0 in
Add this calculator to your website

Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.

How to use it

  1. 01Measure the height from the ground at the foot of the ramp to the floor at the door. Use a level and a tape, not the number of steps.
  2. 02Choose the rule that applies where you build. For a garage or garden ramp that is not for wheelchairs, set your own slope.
  3. 03Read the length of the ramp, the number of runs and the landings between them.
  4. 04Add the level landings at the top and bottom, and check that the ramp fits on your site before you order materials.

How it is calculated

Every accessibility rule limits two things: how steep a ramp may be, and how far a wheelchair user has to push before a level landing to rest. The calculator splits the height into equal runs that stay inside both limits.

Runs (ADA)
n = ceil(rise / 30 in), going = rise per run × 12
Runs (DIN 18040)
n = ceil(rise / 0.06 / 6 m), going = rise per run / 0.06
Approved Document M
steepest gradient 1:(10 + going in m), from 1:12 at 2 m to 1:20 at 10 m
Length
n × going + (n − 1) × landing

ADA (United States): running slope at most 1:12, each run at most 30 in high, level landings 60 in long at the top, the bottom and between runs, 36 in clear width, handrails on both sides above 6 in of rise.

DIN 18040 (Germany): at most 6 % and no cross slope, a landing 150 cm long after at most 6 m, level areas of 150 × 150 cm at both ends, usable width at least 120 cm.

Approved Document M (England and Wales): the longer a flight, the gentler it must be. Table 1 gives 1:12 for 2 m, 1:15 for 5 m and 1:20 for 10 m, and allows interpolation (1:14 at 4 m). No flight may rise more than 500 mm. Landings are 1.2 m at the foot and head and 1.5 m between flights, the width at least 1.5 m. The calculator tries every number of flights and keeps the shortest ramp.

These are the rules for public buildings and, in the US, for places covered by the ADA. Rules for private homes can differ; ask the local building authority.

Worked example

A 45 cm step at a front door, DIN 18040

  1. 45 cm at 6 % needs 7.5 m of ramp. That is more than 6 m, so two runs.
  2. Each run: 22.5 cm high and 3.75 m long, with a 1.5 m landing between them.
  3. Ramp length: 2 × 3.75 + 1.5 = 9.0 m, plus 1.5 m of level space at each end: 12 m in all.
  4. The same 18 in step under the ADA: one run of 18 ft at 1:12, plus 5 ft landings at each end.

Getting the order right

Turn the ramp to save space

A ramp does not have to be straight. Runs can turn at a landing; the ADA asks for a landing of 60 × 60 in where the ramp changes direction.

Measure on the real ground

A garden path that falls away from the house adds height. Measure the height where the ramp will start, not at the wall.

Plan the drainage

Outdoor ramps need water to run off. DIN 18040 asks for drainage on outdoor ramps; keep landings level but not dished.

Check the door

The landing at the door must stay clear of the door swing, so the door can be opened from a wheelchair.

Common mistakes

  • Counting steps instead of measuring the height.
  • Taking the steepest slope as the target. It is the limit; where there is room, a gentler slope is easier to push and to walk.
  • Leaving out the landings at the top and bottom when checking if the ramp fits.
  • Forgetting the kerb or rail along an open edge, so a wheel can roll off the side.

Questions

How long does a wheelchair ramp need to be?

Under the ADA, 1 ft of ramp for every inch of height, so 12 in of rise needs 12 ft, plus landings. Under DIN 18040, about 16.7 cm of ramp per centimetre of height.

What is the maximum slope for a wheelchair ramp?

1:12 (8.3 %) under the ADA, 6 % under DIN 18040, and between 1:12 and 1:20 under Approved Document M, depending on the length of the flight.

When does a ramp need handrails?

Under the ADA, when the rise is more than 6 in. Approved Document M asks for handrails on both sides of every ramp.

How wide should a ramp be?

At least 36 in (ADA), 120 cm (DIN 18040) or 1.5 m (Approved Document M), measured between handrails or kerbs.

Guides on this topic

Sources

  1. [1]Guide to the ADA Accessibility Standards, Chapter 4: Ramps and Curb Ramps. U.S. Access Board. ADA 2010 Standards, 405: running slope 1:12 maximum, cross slope 1:48 maximum, rise of a run 30 in maximum, clear width 36 in minimum, landings 60 in long at top, bottom and between runs (60 × 60 in where the ramp turns), handrails on both sides when the rise is greater than 6 in, handrail height 34 to 38 in.. Checked November 11, 2026
  2. [2]Approved Document M, Access to and use of buildings, Volume 2 (Wales, 2025), para 1.26 and Table 1. Welsh Government. Maximum gradient by going of a flight: 2 m 1:12 (166 mm rise), 5 m 1:15 (333 mm), 10 m 1:20 (500 mm), interpolated between (1:14 at 4 m, 1:19 at 9 m); no flight longer than 10 m or higher than 500 mm; width at least 1.5 m; landings 1.2 m at foot and head, intermediate landings 1.5 m; handrail on both sides; steps in addition above 300 mm total rise; another way up such as a lift above 2 m. Same table as Approved Document M Volume 2 for England.. Checked November 11, 2026
  3. [3]Hinweise zum barrierefreien Bauen nach DIN 18040 (Merkblatt 202, 05/2017). Architektenkammer Niedersachsen. DIN 18040-1 and -2: ramp runs at most 6 % with no cross slope; an intermediate landing 150 cm long after at most 600 cm; level areas of 150 × 150 cm at the start and end; usable width at least 120 cm.. Checked November 11, 2026

Formulas and sources last checked on November 11, 2026. How we calculate