Skip to content
Yardox

Tile calculator

Count the tiles row by row for floors and walls, subtract doors and windows, and get the boxes, adhesive and grout to buy.

Surfaces to tile

01Surface 1
Surface 1: Straight10 ft8 ft

Tile and layout

in

The side laid along the surface width.

in
in
in

Used for grout only: thicker tiles have deeper joints.

Layout

%

For breakage and later repairs. Breakage in transit alone is often 2–4 %.

Boxes

Adhesive and grout

Values from the Ceresit CM 11 data sheet. Other adhesives differ, so check your bag.

lb

Grout makers use the same formula with their own factor.

lb
Tiles to buy84 tiles
Add this calculator to your website

Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.

How to use it

  1. 01Enter the width and length of the floor, or the width and height of each wall. Add one surface per wall: tiles are counted row by row, so a whole room entered as one long wall gives a different count from four separate walls.
  2. 02Subtract doors, windows, a bath or a shower tray. Only the tiles that fit completely inside the opening are taken off, because tiles around the edge still have to be cut.
  3. 03Enter the tile size, the joint width and the tile thickness. Use the real size printed on the box, for example 297 × 597 mm rather than "30 × 60".
  4. 04Choose the layout. Straight and brick layouts are counted tile by tile; diagonal and herringbone are estimated from the area plus an allowance for cuts.
  5. 05Add spare tiles for breakage and future repairs, and the box size if you want the number of boxes. Then pick the trowel notch and the grout to get adhesive and grout.

How it is calculated

For straight and brick layouts we count tiles the way a tiler lays them: how many fit in a row, how many rows fit the surface. A row of n tiles with joints between them is n·a + (n − 1)·j long, so the number of tiles in a row is the smallest n for which that reaches the width.

Tiles in a row
n = ⌈(W + j) / (a + j)⌉
Rows
r = ⌈(H + j) / (b + j)⌉
Straight
tiles = n × r − whole tiles inside openings
Brick (½ offset)
every second row: ⌈(W + j) / (a + j) + ½⌉
Diagonal, herringbone
tiles = S / ((a + j)(b + j)) × (1 + cuts)
To buy
⌈ tiles × (1 + spare) ⌉
Adhesive
kg = S × consumption for the notch
Grout
kg/m² = (A + B) / (A × B) × C × D × factor

Every cut piece at the edge counts as a whole tile, and we do not assume that an offcut from one side will fit the other side. That keeps the count on the safe side; a careful tiler can sometimes save a few tiles.

For an opening we subtract only the tiles that will fall completely inside it whatever the position of the grid: ⌊(w − a) / (a + j)⌋ across times the same down. A 0.9 m door on a wall of 300 mm tiles saves one column, not three.

Diagonal and herringbone are not counted tile by tile, so we divide the area by the area of one tile with its joint and add an allowance for cuts. Clé Tile recommends at least 15 % overall when cuts are not counted; Alpine Floor gives 10–15 % for herringbone and up to 20 % for rooms with many corners.

Grout uses the formula printed in grout data sheets, with sizes in millimetres: A and B are the tile sides, C the tile thickness and D the joint width. MAPEI gives a factor of 1.6 for Ultracolor Plus; Sika writes the same formula for SikaCeram Tile Grout with sizes in centimetres and 140 g/m², which is a factor of 1.4.

We round up only once, at the very end, so rounding does not stack up between steps.

Worked example

Bathroom floor 2.0 × 1.5 m, tiles 300 × 300 × 8 mm, 2 mm joints

  1. Tiles in a row: (2000 + 2) / (300 + 2) = 6.63, so 7. Rows: (1500 + 2) / 302 = 4.97, so 5. Straight layout: 7 × 5 = 35 tiles.
  2. With 5 % spare: 35 × 1.05 = 36.75, so 37 tiles. In a brick layout every second row needs one more tile: 3 × 7 + 2 × 8 = 37 before the spare.
  3. Adhesive with an 8 mm notch: 3 m² × 3.4 kg/m² = 10.2 kg, one 25 kg bag.
  4. Grout with factor 1.6: (300 + 300) / (300 × 300) × 8 × 2 × 1.6 = 0.171 kg/m², so 3 m² × 0.171 = 0.51 kg.

Getting the order right

Buy all tiles from one batch

Tiles from different production runs can differ slightly in shade and size. The batch (lot) number is printed on the box. Buy the spare tiles at the same time, because the same batch may not be available later.

How many spares?

Keep a few tiles after the job for repairs: replacing a cracked tile years later is easy only if you have the same tile. Breakage in transit alone is often 2–4 %. For large-format or fragile tiles, add more.

Notch size and tile size go together

Bigger tiles need a deeper notch so that the back is fully bedded. In the Ceresit CM 11 data sheet the 8 mm notch is for tiles up to 25 cm and the 10 mm notch for tiles up to 30 cm. For larger tiles use the consumption from your adhesive's data sheet.

Common mistakes

  • Entering the nominal size ("30 × 60") instead of the real size printed on the box.
  • Adding a waste percentage on top of a row-by-row count that already counts every cut piece as a whole tile.
  • Subtracting the full area of a door or window. Tiles around the opening still need to be cut from whole tiles.
  • Using the same allowance for diagonal or herringbone as for a straight layout.
  • Ordering the exact count with no spare tiles for breakage and later repairs.

Questions

How many tiles do I need for 10 m²?

For 300 × 300 mm tiles with 2 mm joints one tile covers 0.302 × 0.302 = 0.0912 m², so 10 m² is about 110 tiles by area. The real count depends on the shape of the room, because the cut tiles at the edges count as whole ones. Enter the room's width and length to count row by row.

How much extra tile should I buy?

For straight and brick layouts counted row by row, 5 % spare is a sensible minimum, because cuts are already counted. For diagonal and herringbone layouts estimated from area, add about 15 % for cuts on top of that.

How much grout do I need per square metre?

It depends on tile size, thickness and joint width. For 300 × 300 × 8 mm tiles with a 3 mm joint, the MAPEI formula gives 0.256 kg/m² and the Sika formula 0.224 kg/m². Small tiles and wide joints need much more grout.

How much tile adhesive per m²?

For Ceresit CM 11 the data sheet gives 2.0 kg/m² with a 4 mm notch, 2.7 with 6 mm, 3.4 with 8 mm and 4.2 with 10 mm. Other adhesives differ, so check the data sheet of the product you buy.

Guides on this topic

  • How much extra tile should I buy?

    Tile overage for cuts, breakage and repairs, how the layout pattern changes the count, boxes, and what the grout joint really affects, with examples.

Sources

  1. [1]Ceresit CM 11 – Technical Data Sheet (11/2023). Henkel. Adhesive consumption by notch depth: 4 mm 2.0 kg/m² (tiles up to 10 cm), 6 mm 2.7 (up to 15 cm), 8 mm 3.4 (up to 25 cm), 10 mm 4.2 (up to 30 cm). Checked November 5, 2026
  2. [2]Ultracolor Plus – Technical Data Sheet (10/2017, UK). MAPEI. Grout consumption formula (A + B) / (A × B) × C × D × 1.6 = kg/m², A, B tile sides, C tile thickness, D joint width, all in mm. Checked November 5, 2026
  3. [3]SikaCeram Tile Grout – Product Data Sheet. Sika. Grout consumption g/m² = joint width × tile thickness × (C + D) / (C × D) × 140, C, D in cm (the same formula with a factor of 1.4). Checked November 5, 2026
  4. [4]Why does the size calculator automatically add 10%?. Clé Tile. Overage for cuts, breakage in transit (2–4 %) and spare tiles; at least 15 % overall when cuts are not counted. Checked November 5, 2026
  5. [5]How Much Extra Herringbone Flooring Do You Need? A Waste Calculation Guide. Alpine Floor. Herringbone waste: 10–15 %, up to 20 % in rooms with many corners and alcoves. Checked November 5, 2026

Formulas and sources last checked on November 5, 2026. How we calculate