Ramp slope: the 1:12 rule, landings and length

A ramp is set by two numbers: how steep it may be and how far it may climb before a level landing. Together they decide how long the ramp gets, and that length is usually the surprise.

Mis à jour le 12 novembre 2026

En bref

Under the ADA a ramp may be no steeper than 1:12, 1 in of rise for every 12 in of length, and one run may climb at most 30 in before a 60 in landing. A 24 in rise therefore needs 24 ft of ramp plus landings at the top and bottom.

Faire le calcul

Calculateur de rampe d'accès

Longueur, paliers et largeur d'une rampe pour fauteuil roulant selon la hauteur à franchir.

Calculateur de rampe d'accès →

Slope, rise and run

Slope is the rise divided by the horizontal length. 1:12 means 1 unit up for every 12 along, which is 8.33 %. A run is one sloped part between level landings. Landings give a place to rest, turn and open doors.

Run ≤ 30 ft60 inRun ≤ 30 ft≤ 30 in per run1:12 max.Landing 60 in
Two runs with a level landing between them. Each run stays within the slope and the rise allowed for one run.

The rules side by side

The ADA standards apply to public and commercial facilities in the United States, Approved Document M Volume 2 to buildings other than dwellings in England and Wales, and DIN 18040 to accessible buildings and dwellings in Germany.

Main ramp limits by rule
ADA (US)Approved Document M (England, Wales)DIN 18040 (Germany)
Steepest slope1:12 (8.33 %)1:12 for a 2 m run, 1:15 for 5 m, 1:20 for 10 m6 %
Longest runRise of 30 in (762 mm)10 m going, 500 mm rise6 m
Landings60 in (1524 mm) at top, bottom and between runs1.2 m at the ends, 1.5 m between runs1.5 m between runs, 1.5 × 1.5 m at the ends
Clear width36 in (914 mm)1.5 m1.2 m
Cross slope1:48 max.—None
HandrailsBoth sides when the rise is more than 6 inBoth sides—

Approved Document M also says that a ramp rising more than 300 mm in total should have steps as well, and above 2 m another way up, such as a lift. Its slopes between the listed run lengths are interpolated: 1:14 for a 4 m run, 1:19 for 9 m.

Worked example: a 24 in porch under the ADA

  • Length of slope: 24 in × 12 = 288 in = 24 ft.
  • Rise of one run: 24 in is below 30 in, so one run is enough.
  • Landings: 60 in at the bottom and 60 in at the top.
  • Total length: 24 ft + 5 ft + 5 ft = 34 ft.
  • Handrails on both sides, because the rise is more than 6 in. Clear width at least 36 in.

A 36 in rise would need two runs of 18 in each, 18 ft long, with a 60 in landing between them.

Worked example: a 50 cm rise under DIN 18040

  • Length of slope at 6 %: 0.50 / 0.06 = 8.33 m.
  • Runs: at most 6 m each, so two runs of 4.17 m with a 1.5 m landing between them.
  • Level areas of 1.5 × 1.5 m at the start and the end.
  • Total length: 8.33 + 1.5 + 1.5 + 1.5 = 12.83 m.

This is why ramps at the entrance of a house often turn back on themselves: 13 m of straight ramp rarely fits in front of a door.

Questions

How long does a ramp need to be?

At 1:12, 12 times the rise: 1 ft of ramp for every 1 in of rise. A 24 in rise needs 24 ft, plus landings.

What is 1:12 as a percentage?

8.33 %. It is about 4.8°.

How often does a ramp need a landing?

Under the ADA after every 30 in of rise. Under DIN 18040 after every 6 m of length. Under Approved Document M after every 10 m of going or 500 mm of rise, and less where the slope is steeper.

How wide should a ramp be?

At least 36 in (914 mm) clear under the ADA, 1.5 m under Approved Document M, and 1.2 m under DIN 18040.

Does a ramp at a private house have to follow the ADA?

The ADA standards are written for public and commercial facilities. For a private home check your local rules; the ADA numbers are a well-documented target if a wheelchair user will use the ramp.

Faire le calcul

Calculateur de rampe d'accès

Longueur, paliers et largeur d'une rampe pour fauteuil roulant selon la hauteur à franchir.

Calculateur de rampe d'accès →

Sources

  1. [1]Guide to the ADA Accessibility Standards, Chapter 4: Ramps and Curb Ramps. U.S. Access Board. ADA 2010 Standards, 405: running slope 1:12 maximum, cross slope 1:48 maximum, rise of a run 30 in maximum, clear width 36 in minimum, landings 60 in long at top, bottom and between runs (60 × 60 in where the ramp turns), handrails on both sides when the rise is greater than 6 in, handrail height 34 to 38 in.. Vérifié le 11 novembre 2026
  2. [2]Approved Document M, Access to and use of buildings, Volume 2 (Wales, 2025), para 1.26 and Table 1. Welsh Government. Maximum gradient by going of a flight: 2 m 1:12 (166 mm rise), 5 m 1:15 (333 mm), 10 m 1:20 (500 mm), interpolated between (1:14 at 4 m, 1:19 at 9 m); no flight longer than 10 m or higher than 500 mm; width at least 1.5 m; landings 1.2 m at foot and head, intermediate landings 1.5 m; handrail on both sides; steps in addition above 300 mm total rise; another way up such as a lift above 2 m. Same table as Approved Document M Volume 2 for England.. Vérifié le 11 novembre 2026
  3. [3]Hinweise zum barrierefreien Bauen nach DIN 18040 (Merkblatt 202, 05/2017). Architektenkammer Niedersachsen. DIN 18040-1 and -2: ramp runs at most 6 % with no cross slope; an intermediate landing 150 cm long after at most 600 cm; level areas of 150 × 150 cm at the start and end; usable width at least 120 cm.. Vérifié le 11 novembre 2026