Dew point calculator
Find the dew point of your room air and check whether the inside of a wall stays dry or gets damp and mouldy on a cold day.
Room air
Dew point from the saturation vapour pressure; inner surface temperature from the U-value with Rsi = 0.25 m²K/W, as in the German mould check (DIN 4108-2).
Room
From a hygrometer. 40–60 % is usual in living rooms in winter.
Wall and outside
The German check uses −5 °C; try your coldest days too.
From the energy certificate or the insulation calculator. An old solid brick wall is often above 1.
Add this calculator to your website
Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.
Cara menggunakan
- 01Enter the room temperature and the relative humidity from a hygrometer.
- 02Enter the outdoor temperature. The German check uses −5 °C; try the coldest days where you live as well.
- 03Enter the U-value of the wall, or its R-value. The insulation calculator or the energy certificate gives it.
- 04Read the dew point, the temperature of the inner wall surface and the humidity right at the surface.
Cara menghitung
Air holds more water vapour the warmer it is. When air touches a surface colder than its dew point, the vapour turns to water. Mould needs less: a surface humidity of about 80 % over a longer time is enough.
- Saturation pressure
- psat = 610.57 × exp(17.177 θ / (235.77 + θ))
- Vapour pressure
- p = φ × psat(θi)
- Dew point
- θd where psat(θd) = p
- Inner surface
- θsi = θi − U × Rsi × (θi − θe)
- Surface humidity
- φsi = p / psat(θsi)
The saturation pressure formula is the one given by Fiedler in TAB (2010), accurate to 0.1 % above 0 °C, with a separate form over ice below 0 °C. With it, 20 °C and 50 % give 1,170 Pa and −5 °C and 80 % give 321 Pa, the values of the German design climate.
For the surface, the German mould check (DIN 4108-2, as described by BauNetz Wissen) uses an inner surface resistance Rsi = 0.25 m²K/W. That is higher than the usual 0.13 because corners and spots behind furniture get less warm air. The requirement fRsi = 1 − U × Rsi ≥ 0.70 means at least about 12.6 °C on the surface at −5 °C outside.
The calculator looks at the surface of a plain wall. Condensation inside a wall build-up needs a layer-by-layer Glaser calculation, and thermal bridges such as window reveals and slab edges can be colder than the wall itself.
Contoh perhitungan
An old solid wall, U = 1.4 W/(m²K), room at 20 °C and 50 %, −5 °C outside
- Vapour pressure: 0.5 × 2,339 Pa = 1,170 Pa. Dew point 9.3 °C.
- Inner surface: 20 − 1.4 × 0.25 × 25 = 11.25 °C, above the dew point, so no water.
- Surface humidity: 1,170 / 1,335 = 88 %. Mould can grow behind the wardrobe.
- fRsi = 1 − 1.4 × 0.25 = 0.65, below the required 0.70.
Tips memesan bahan
Measure the humidity for a week
A cheap hygrometer shows how humidity moves with cooking, showers and drying laundry. Use the high values, not the average.
Keep furniture off cold outer walls
A few centimetres of gap let warm air reach the wall. Behind a wardrobe pressed against the wall the surface is several degrees colder.
Insulation helps most
A better U-value warms the inner surface. Halving the U-value halves the drop between room and surface.
Kesalahan umum
- Using the room average humidity from a heated living room for the bedroom. Bedrooms are cooler and often more humid at night.
- Taking the U-value of the insulation layer alone. Use the whole wall.
- Assuming no water means no mould. Mould grows at surface humidity well below 100 %.
- Insulating on the inside without checking the build-up. Condensation inside the wall needs a Glaser calculation.
Tanya jawab
What is the dew point at 20 °C and 50 % humidity?
About 9.3 °C. Any surface colder than that gets wet in that air.
Why do walls get mouldy without visible water?
Mould needs only a high humidity at the surface, about 80 % over a longer time. A cool wall surface reaches that long before water appears.
What indoor humidity is safe?
It depends on the wall. The calculator shows the highest room humidity at which the wall surface stays under 80 % for your U-value and outdoor temperature.
What does fRsi 0.7 mean?
The surface temperature factor: the inner surface is at least 70 % of the way from the outdoor to the room temperature. The German code requires it to avoid mould at 20 °C and 50 % inside.
Sumber
- [1]Berechnung feuchter Luft (E. Fiedler, TAB 11/2010, pp. 52–56). TAB – Technik am Bau. Saturation vapour pressure ps = 610.57 × exp(z), z = 17.177 t / (235.77 + t) for t ≥ 0 °C and z = 22.52447 t / (273.15 + 0.998064758 t) below 0 °C; better than 0.1 % from 0 to 90 °C. Inverted for the dew point.. Diperiksa 11 November 2026
- [2]Tauwasser auf/in Bauteilen (after DIN 4108-2 and 4108-3). BauNetz Wissen. Inner surface resistance Rsi = 0.25 m²K/W for the check; requirement fRsi ≥ 0.7, i.e. at least 12.6 °C on the surface at −5 °C outside and 20 °C, 50 % inside.. Diperiksa 11 November 2026
- [3]Tauwasser und Glaser-Verfahren. BauNetz Wissen. Winter design climate: inside 20 °C and 50 % (1,168 Pa), outside −5 °C and 80 % (321 Pa), December to February.. Diperiksa 11 November 2026
Rumus dan sumber terakhir diperiksa pada 11 November 2026. Cara kami menghitung