Metal roof
Count the metal roofing panels to order and the length to cut them, with screws and trim, for R-panel, corrugated, standing seam or Custom Orb sheets.
Roof
Roof shape
Measure along the bottom edge of one side, including the rake overhangs.
Measured flat, not along the slope. The calculator adds the slope.
How far the panels run past the eave edge, as your trim detail shows.
Panel
The width one panel covers once lapped, from the panel's data sheet, not its full width.
Longest panel the manufacturer recommends or ships. A longer run is split into rows with an end lap. 0 for no limit.
Overlap where two panels meet along the slope. Best Buy Metals asks for at least 6 in on R-panel.
Додайте цей калькулятор на свій сайт
Калькулятор безкоштовний для будь-якого сайту. Вставте код туди, де має з'явитися калькулятор. Калькулятор оновлюється автоматично, підлаштовує висоту під вміст і містить посилання на повну сторінку з поясненнями.
Як користуватися
- 01Pick a gable roof (two sides) or a shed roof (one side).
- 02Enter the length along the eave of one side and the run from eave to ridge, measured flat, then the pitch.
- 03Pick the panel. The cover width and the longest panel fill in from the manufacturer’s data sheet; change them for your own panel.
- 04Read the number of panels and the length to cut them, then the screws and the trim lengths.
Як виконується розрахунок
A 40 ft gable roof with a 12 ft run at 4/12 takes 28 R-panels of 36 in cover, each 12 ft 7.8 in long. Metal panels are ordered cut to length, so the calculator does not divide the roof area by the panel area: it counts panels across the eave and cuts each one to the length along the slope.
- Across one side
- ⌈eave length ÷ cover width⌉
- Slope length
- run × √(1 + pitch²) + overhang
- Rows
- 1, or ⌈(slope length − end lap) ÷ (longest panel − end lap)⌉ when the slope is longer than the longest panel
- Panels
- across × rows × sides
- Stitch screws
- (across − 1) × ⌈slope length ÷ 12 in⌉ × sides
Cover widths, slopes and lengths come from the manufacturers’ data sheets. Metal Sales PBR covers 36 in, has a minimum slope of 1:12 and is recommended up to 45 ft long. Metal Sales 2.5 in corrugated covers 21 1/3 in, needs 3:12 without side-lap sealant (the sheet notes that the IBC allows as low as 1/2:12 with it) and goes up to 30 ft. ABC SL-16 standing seam covers 16 in and needs 3:12. Lysaght Custom Orb covers 762 mm, goes down to 5°, and runs up to 24 m before an expansion joint.
The cover width is the width a panel covers once it overlaps its neighbor, not its full width: Berridge’s R-Panel is 38 1/4 in wide and covers 36 in.
Screws: Berridge estimates 115 fasteners per square (100 sq ft) for its R-Panel, and the calculator shows that figure for R and PBR panels only. Both Metal Sales sheets put a stitch screw every 12 in along each side lap. Standing seam is fastened with concealed clips, and Custom Orb through the crests at least 25 mm (1 in) from the sheet end (Lysaght), so follow those sheets for the count.
Trim is given in length: the ridge cap (or the high-side trim on a shed roof) runs the length of the eave, eave trim runs along each eave, and rake trim runs up both ends of each side. Best Buy Metals laps trim pieces 4 in at rakes and valleys.
Приклад розрахунку
A 40 × 24 ft gable at 4/12 and a 12 m roof in Custom Orb
- Gable, 40 ft (12.2 m) along each eave, 12 ft (3.66 m) run per side, 4/12 pitch, R/PBR panel 36 in (914 mm) cover.
- Across: 40 ft ÷ 3 ft = 13.3, so 14 panels per side. Slope: 12 × √(1 + (4/12)²) = 12.65 ft, or 12 ft 7.8 in (3.86 m). 28 panels in all, 354 ft (108 m) of panel.
- Area 1,012 sq ft (94 m²), 10.12 squares, about 1,164 panel screws at 115 per square, and 2 × 13 laps × 13 = 338 stitch screws. Trim: 40 ft ridge cap, 80 ft eave, 50.6 ft rake.
- The same roof in 2.5 in corrugated: 40 ft ÷ 21 1/3 in = 22.5, so 23 per side and 46 panels. In 16 in standing seam: 30 per side, 60 panels.
- Metric: 12 m eave, 4 m run per side at 20°, Custom Orb 762 mm: 12 ÷ 0.762 = 15.7, so 16 sheets per side, 32 sheets of 4,257 mm.
- A 50 ft (15.2 m) shed run at 1:12 is longer than the 45 ft PBR limit, so it takes two rows with a 6 in (152 mm) end lap: each panel is 25 ft 4.0 in (7.72 m).
Як правильно замовити
Measure the run flat
Enter the run as a flat, horizontal distance, from a plan or measured below the roof, and let the pitch add the slope. Then add the overhang your eave detail calls for.
Check the minimum slope first
Minimum slopes differ by profile: 1:12 for Metal Sales PBR, 3:12 for 2.5 in corrugated (without side-lap sealant) and for SL-16 standing seam, 5° for Custom Orb. Best Buy Metals asks for butyl tape on R-panel laps under 3:12. The calculator warns when your pitch is below the profile’s minimum.
Order by the cut list
Panels are cut to length at the plant, so give the supplier the number of panels and the length, not square feet. Long runs are limited by what the plant makes: Berridge makes R-Panel up to 40 ft, Metal Sales recommends PBR up to 45 ft.
Поширені помилки
- Dividing the roof area by the panel area: on the example roof that gives 1,012 ÷ (3 × 12.65) = 26.7 panels, fewer than the 28 that fit across two 40 ft eaves.
- Using the full panel width instead of the cover width: a 38 1/4 in R-Panel covers 36 in.
- Measuring the run along the slope and then entering the pitch too, which adds the slope twice.
- Laying corrugated panels at less than 3:12 without the side-lap sealant the data sheet calls for.
Запитання
How many metal roofing panels do I need?
Divide the length along the eave by the panel’s cover width and round up, then multiply by the number of roof sides. A 40 ft gable needs 14 R-panels of 36 in per side, 28 in all.
How long should metal roof panels be?
The run times the slope factor plus the overhang. A 12 ft run at 4/12 is 12 ft 7.8 in along the slope before any overhang.
How many screws per square for metal roofing?
Berridge estimates 115 fasteners per square for its 36 in R-Panel. Add stitch screws every 12 in along each side lap. Other panels have their own fastening patterns.
What is the minimum pitch for a metal roof?
It depends on the panel: 1:12 for Metal Sales PBR, 3:12 for 2.5 in corrugated without sealant and for SL-16 standing seam, 5° (about 1 in 12) for Lysaght Custom Orb.
Пов'язані калькулятори
Джерела
- [1]PBR Panel, product data (©MSMC 1-2026). Metal Sales. 36 in coverage, trapezoidal rib on 12 in centers, 1 1/4 in rib height; minimum roof slope 1:12; side lap fastener (1/4-14 × 7/8 in stitch screw) spaced 12 in on center; length minimum 5 ft, maximum 45 ft recommended. Перевірено 21 листопада 2026 р.
- [2]2.5" Corrugated, product data (©MSMC 1-2024). Metal Sales. 21 1/3 in coverage, ribs on 2 2/3 in centers, 1/2 in rib height; minimum slope 3:12 without sidelap sealant (IBC allows down to 1/2:12 with sidelap sealant); sidelap fastener 12 in on center; length 3 ft 6 in minimum, 30 ft maximum recommended. Перевірено 21 листопада 2026 р.
- [3]"R" Panel data sheet (2024). Berridge Manufacturing. 36 in coverage (38 1/4 in actual width); "Estimate 115 fasteners/sq."; continuous lengths to a maximum of 40 ft; mastic sealant tape at end laps and side laps. Перевірено 21 листопада 2026 р.
- [4]R-Panel installation guide. Best Buy Metals. End lap 6 in minimum; minimum pitch 1:12, butyl tape under 3:12; trim screws every 12 in at eave and rake, every 18 in at ridge and hip; trim overlap 4 in at rake and valley. Перевірено 21 листопада 2026 р.
- [5]SL-16 standing seam, product data sheet. ABC Metal Roofing. 16 in coverage; minimum slope 3:12; concealed fastening. Перевірено 21 листопада 2026 р.
- [6]Custom Orb and Custom Blue Orb brochure. Lysaght. 762 mm cover; minimum pitch 5° (1 in 12); end laps not usually necessary; side lap not less than 1.5 corrugations; fasteners through crests at least 25 mm from the sheet end; sheets up to 24 m before an expansion joint. Перевірено 21 листопада 2026 р.
Формули та джерела востаннє перевірено 21 листопада 2026 р.. Як ми рахуємо