Insulation thickness calculator
Find how thick the insulation must be to reach a target U-value or R-value, counting the layers already in the wall, roof or floor.
Target
Your local code gives it, usually by climate zone. Check before you buy.
New insulation
On the bag or board: R-value divided by thickness in inches.
The result is rounded up to this.
Add this calculator to your website
Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.
How to use it
- 01Choose the target. For a US home that is usually the insulation R-value your local code asks for in your climate zone. For a whole-element U-value, choose the U option.
- 02Enter the R-value per inch printed on the batts, boards or bags you plan to use.
- 03With a U-value target, add the layers that stay (sheathing, masonry, old insulation) if you know their data. If not, leave them out: the answer is then on the safe side.
- 04Read the thickness to buy, rounded up to the step you set.
How it is calculated
Each layer resists heat by its thickness divided by its conductivity. Add the resistances, including the thin air films on both surfaces, and the U-value is one over the sum.
- Layer
- R = d / λ
- Element
- U = 1 / (Rsi + Σ d / λ + Rse)
- Insulation needed for a U target
- R = 1 / U − Rsi − Rse − R existing
- Thickness
- d = λ × R, rounded up
- US units
- R-1 = 0.1761 m²K/W; λ = 1 in / (R per inch)
Surface resistances after ISO 6946 as given in BRE BR 443: walls 0.13 inside and 0.04 outside, roofs 0.10 and 0.04, floors 0.17 and 0.04 m²K/W.
German GEG Anlage 7 sets the maximum U-values when an element of a house is renewed: external walls 0.24, pitched roofs and top-floor ceilings 0.24, flat roofs 0.20, elements to unheated rooms or ground 0.30 W/(m²K).
The calculation leaves out thermal bridges at studs and fixings and the corrections of ISO 6946 for air gaps. A framed wall with batts between studs performs worse than the batt R-value alone.
Worked example
R-21 of insulation with batts at R-3.7 per inch
- Thickness: 21 / 3.7 = 5.68 in.
- Rounded up to whole inches: 6 in.
- In SI: R-21 = 3.70 m²K/W; λ = 0.0254 / (3.7 × 0.1761) = 0.039 W/mK.
Getting the order right
Read the label, not the brochure
The R-value or λ on the product label is the declared value you are allowed to calculate with.
Mind the framing
Studs and joists conduct heat. Continuous insulation outside the framing works better than thicker batts between it.
Moisture first
More insulation moves the dew point. Check the vapour control layer before you add a thick layer inside.
Common mistakes
- Adding R-values of products with the surface films counted twice.
- Using a U-value target as if it were the insulation R alone.
- Ignoring compression: squashed batts lose R-value.
- Rounding down to the next stock size.
Questions
How thick for R-21?
At R-3.7 per inch, 5.68 in. Other products differ: divide 21 by the R per inch on the bag.
How do I convert R-value to RSI?
Multiply by 0.1761. R-21 is RSI 3.70.
What is the U-value of a wall?
One over its total thermal resistance: the layers plus the two surface resistances.
Does this replace an energy calculation?
No. It ignores thermal bridges and fixings. For a permit or subsidy, an energy consultant must calculate the element.
Guides on this topic
- How thick should insulation be for a given U-value?
Work out insulation thickness from a target U-value or R-value and the board's lambda, with BR 443 surface resistances and German GEG limits.
Related calculators
Sources
- [1]Conventions for U-value calculations, BR 443 (2019 edition). BRE, Brian Anderson and Ludmilla Kosmina. U = 1 / ΣR after BS EN ISO 6946. Surface resistances in m²K/W: walls (horizontal flow) Rsi 0.13, Rse 0.04; roofs (upward) 0.10, 0.04; floors (downward) 0.17, 0.04.. Checked November 5, 2026
- [2]Gebäudeenergiegesetz (GEG), Anlage 7: Höchstwerte der Wärmedurchgangskoeffizienten bei Änderung. Bundesministerium der Justiz, gesetze-im-internet.de. Residential buildings, when an element is renewed: external walls 0.24 W/(m²K); pitched roofs, top-floor ceilings and walls to unheated roof spaces 0.24; flat roofs 0.20; walls and ceilings to unheated rooms or ground 0.30.. Checked November 5, 2026
Formulas and sources last checked on November 5, 2026. How we calculate