Lighting calculator

Find how many ceiling lights or downlights a room needs for the brightness you want, and where to put them.

Your room

Enter the size of the room and the light output of one light. You get how many lights to fit, where to put them and how bright the room will be.

Ceiling plan of the room with the lights in an even grid5 m4 m0.63 m1.25 m

Room and brightness

Recommended: 10 fc (IES via US Department of Energy). Change the brightness to your own taste.

lx

Average light on the floor, table or worktop. Older eyes need more.

m
m
m

Floor to ceiling, where the lights are fixed.

Lights

Type of light

lm

Printed on the box or the data sheet, in lumens (lm). Not the watts.

W

Optional, for the power of all lights together.

Room surfaces, spacing and light data

Walls and ceiling

White ceiling and pale walls reflect light back into the room, so fewer lights are needed.

m

Table or worktop height; 0 to light the floor.

m

Empty: half the ceiling height, at most 6 ft (1.83 m), here 1.3 m. Enter 0 for no spacing rule.

Empty: from a downlight table by room shape and colour. With the data sheet of your light, enter its own value.

0.8 for LED lights in a clean room, cleaned every few years.

Lights to fit16 lights
Add this calculator to your website

Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.

使い方

  1. 01Choose the room. The brightness fills in with the recommended level for it; change it if you like the room brighter or softer.
  2. 02Enter the length, width and ceiling height of the room.
  3. 03Choose downlights or ceiling lights, and enter the light output of one light in lumens from the box or data sheet.
  4. 04Read how many lights to fit, the grid, the gap between them and how far the first row sits from the wall.
  5. 05Under "Room surfaces" you can set dark walls, the height of the table or worktop, your own spacing and the factors from the data sheet of your light.

計算方法

The calculator uses the lumen method that lighting designers use for even general light: the target level on the surface times the floor area, divided by the share of lamp light that arrives there and by an allowance for ageing and dust.

Room index
K = L × W / ((L + W) × Hm)
Lamp light needed
Φ = E × A / (UF × MF)
Number of lights
N = Φ / Φ one light, rounded up
Downlight spacing
s ≤ ceiling height / 2, at most 6 ft (1.83 m)

Hm is the height of the lights above the lit surface. The room index K describes the shape of the room: in a small or tall room a larger share of the light falls on the walls, so less of it reaches the floor or the table.

The utilisation factor UF comes from the published table of a Philips recessed LED downlight, for three room colours: light (ceiling 70 %, walls 50 %, floor 20 % reflectance), medium (50/30/10) and dark (30/10/10). Between the columns of the table the value is interpolated. Your own light may differ; with its data sheet you can enter its own factor.

The maintenance factor MF allows for LEDs losing output with age and for dust on the lights and the room. 0.8 is the value of a worked example for LED lights in a clean room, cleaned every three years.

The brightness levels for homes come from the IES Lighting Handbook, as published by the US Department of Energy, and from licht.de, the German lighting industry association. There is no binding European standard for homes: EN 12464-1 covers workplaces.

For downlights the calculator also keeps the gap between lights at no more than half the ceiling height and 6 feet, as Kichler recommends, so the light is even. The outer lights sit half a gap from the walls, but no closer than 2 ft (0.6 m), so the walls do not get bright scallops. When the spacing rule needs more lights than the brightness does, it says how many lumens each light then needs; or fit them on a dimmer.

計算例

A 5 × 4 m kitchen with a 2.6 m ceiling and 600 lm downlights

  1. Target 500 lx on a worktop 0.75 m high: Hm = 2.6 − 0.75 = 1.85 m.
  2. Room index K = 20 / (9 × 1.85) = 1.20, utilisation factor 0.70 for a light room.
  3. Lamp light: 500 × 20 / (0.70 × 0.8) = 17,700 lm, which is 30 lights of 600 lm.
  4. The grid is 5 rows of 6 lights, giving about 510 lx. Half a gap from the walls would be only 0.4 m, so the outer lights move in to 0.6 m (2 ft) and the rest sit 0.76 × 0.70 m apart.
  5. With 1,200 lm lights the brightness needs 15, but the gap of at most 1.3 m (half the ceiling height) asks for a 4 × 4 grid of 16.

発注時のポイント

Compare lumens, not watts

Two LEDs of the same wattage can give very different light. The lumen figure on the box is what counts.

Light the task, not only the room

A kitchen worktop, a mirror or a desk needs much more light than the rest of the room. Under-cabinet strips or a mirror light often do that better than more downlights.

Put the lights on a dimmer

An even grid for a working kitchen is too bright for dinner. A dimmer lets the same lights do both.

Keep the grid away from cupboards

Downlights in front of tall cupboards throw shadows into them. In a kitchen, centre a row over the front edge of the worktop.

よくある間違い

  • Counting lights by watts from old incandescent bulbs.
  • Spacing downlights by eye and leaving dark corners.
  • Using the same brightness for a hallway and a kitchen worktop.
  • Forgetting that dark walls and ceilings swallow light.

よくある質問

How many lumens does a room need?

The target level times the floor area, divided by the share of light that reaches it. For a 20 m² kitchen at 500 lx that is about 17,700 lm from the lamps.

How far apart should downlights be?

Kichler recommends half the ceiling height between lights, no more than 6 feet, and at least 2 feet from the walls. In an 8 ft room that is a 4 ft grid.

How bright should a kitchen be?

licht.de recommends 500 lx in the kitchen. The IES recommends 50 footcandles (about 540 lx) on the preparation counter and 5 footcandles for general kitchen light.

What is a utilisation factor?

The share of the lamp light that reaches the surface you light. It depends on the light, the shape of the room and the colour of its walls and ceiling; makers publish it in the data sheet.

出典

  1. [1]Strategy Guideline: High Performance Residential Lighting (J. Holton, IBACOS, February 2012), Table 1. U.S. Department of Energy, Building America. Recommended horizontal illuminance for homes after the IES Lighting Handbook, 10th ed., Table 33.2 (occupants 25 to 65): living room 3 fc, family room 10 fc, bedroom 5 fc, informal dining 10 fc, hallway 3 fc, stairs 5 fc, laundry 20 fc, garage 5 fc, walk-in closet 30 fc, kitchen prep counter 50 fc, bath vanity 30 fc, home office 20 fc.. 確認日: 2026年11月18日
  2. [2]licht.wissen 14: Licht für Wohnräume. licht.de (Fördergemeinschaft Gutes Licht, ZVEI). Kitchen 500 lx; bathroom general lighting 300 lx; reading, homework and home office 500 lx.. 確認日: 2026年11月18日
  3. [3]General uniform lighting: DN027B G3 LED6 NW 6W D90 recessed downlight, utilisation factors. Signify (Philips Lighting). Utilisation factors of a ceiling-mounted LED downlight by room index k = 0.60 to 5.00, for reflectances ceiling/walls/working plane 0.70/0.50/0.20, 0.50/0.30/0.10 and 0.30/0.10/0.10.. 確認日: 2026年11月18日
  4. [4]Lighting Design Guide (CLS-CC2454, November 2013). Eaton's Cooper Lighting and Safety. Lumen method E = F × N × MF × UF / A and room index K = L × W / ((L + W) × Hm), Hm = height of the luminaire above the working plane.. 確認日: 2026年11月18日
  5. [5]Planning and calculation tips: maintenance factor. Fagerhult. Maintenance factor MF = LLMF × LSF × LMF × RSMF; worked example for an LED luminaire in a clean room, cleaned every 3 years: 0.9 × 1 × 0.94 × 0.95 = 0.8.. 確認日: 2026年11月18日
  6. [6]Downlight and recessed lighting placement tips. Kichler Lighting. Spacing between downlights = ceiling height / 2, but no more than 6 ft apart; start no less than 2 ft from the walls.. 確認日: 2026年11月18日

計算式と出典の最終確認日: 2026年11月18日。 計算方法