Ventilation calculator

Find how much fresh air your home needs around the clock, and how strong the bathroom and kitchen fans should be.

Your home

Whole-house rate after ASHRAE 62.2: a share for the floor area plus a share per occupant, counted as bedrooms plus one. Bathroom and kitchen fans after the same standard.

Section through a home: fresh air comes in, bathroom and kitchen air goes outbedroomkitchenbath93 m³/h85 m³/h170 m³/h

Size and occupants

m²

All heated rooms together, as on the floor plan.

m

Used for the air changes per hour and the kitchen rate.

0 for a studio.

Every room with a toilet, shower or bath.

Bathroom and kitchen fans

Fans run

Kitchen

Fresh air for the whole home93 m³/h
Add this calculator to your website

Free for any website: paste this code where the calculator should appear. It keeps itself up to date, fits its height to the content and links back to the full page with the explanations.

使い方

  1. 01Enter the heated floor area of the home and the ceiling height.
  2. 02Enter the number of bedrooms. The rate counts one occupant per bedroom plus one more.
  3. 03Enter the number of bathrooms and toilet rooms, and choose what kind of kitchen you have.
  4. 04Choose whether the bathroom and kitchen fans run only when needed or all the time.
  5. 05Read the fresh-air rate for the whole home. A ventilation unit or a set of fans should deliver at least that, day and night.

計算方法

The whole-house rate follows ASHRAE Standard 62.2, the US standard for ventilation in homes. It has two parts: one for the floor area, which covers what the building, furniture and finishes give off, and one per occupant.

Whole home (cfm)
Q = 0.03 × A(ft²) + 7.5 × (bedrooms + 1)
Whole home (L/s)
Q = 0.152 × A(m²) + 3.54 × (bedrooms + 1)
Air changes per hour
n = Q(m³/h) / (A × height)
Enclosed kitchen, continuous
Q = 5 × kitchen volume per hour

The metric form is the same rule converted exactly: 0.03 cfm per ft² is 0.1524 L/s per m², and 7.5 cfm is 3.54 L/s. The 2013 edition raised the floor-area share from 0.01 to 0.03 cfm per ft², and the 2016 edition kept it.

Bathroom and kitchen fans come from the local exhaust tables of the standard: 50 cfm (25 L/s) for a bathroom fan switched on when needed, or 20 cfm (10 L/s) running all the time; 100 cfm (50 L/s) for a range hood vented outside, or 5 air changes per hour for an enclosed kitchen with a continuous fan. There is no continuous rate for an open kitchen, so it needs a hood.

The standard lets you subtract part of the rate when a blower door test shows how much air leaks in by itself. The calculator does not take that credit, so the rate is on the safe side for a tight house.

For comparison the calculator shows air changes per hour. The European heat load method (EN 12831) assumes at least 0.5 per hour in living rooms. National rules in Europe, such as DIN 1946-6 in Germany, set their own rates; check the one that applies where you build.

計算例

A 100 m² flat with two bedrooms and 2.5 m ceilings

  1. Floor area: 100 × 0.1524 = 15.24 L/s, which is 55 m³/h.
  2. Occupants: 2 bedrooms + 1 = 3 people, 3 × 3.54 = 10.62 L/s, which is 38 m³/h.
  3. Whole home: 25.86 L/s, about 93 m³/h, all the time.
  4. Volume 250 m³: 93 / 250 = 0.37 air changes per hour.
  5. Bathroom fan 25 L/s (90 m³/h) when used, range hood 50 L/s (180 m³/h) when cooking.

発注時のポイント

Size the unit for the whole-home rate

A heat recovery unit or a central exhaust fan should reach the whole-home rate at a low, quiet setting, with room to boost when cooking or showering.

Check the fan rating at real pressure

Fan ratings are measured at one low duct pressure. Long or narrow ducts, bends and grilles cut the airflow, so compare the fan curve at the pressure of your duct run.

Give the air a way in and out

An exhaust fan only moves the air it can replace. Doors need a gap at the bottom or a transfer grille, and a tight house needs supply openings or a balanced system.

Vent the hood outside

Only a hood that blows outside counts in the standard. A recirculating hood filters grease but leaves moisture and smells in the room.

よくある間違い

  • Counting only bathroom fans as the ventilation of the home. They run when the room is used, but the bedrooms need fresh air all night.
  • Choosing a fan by its label rating without counting the duct.
  • Leaving out the occupant share in a small flat. In a studio it can be larger than the floor-area share.
  • Copying the US rate for a home in Europe without checking the national rule.

よくある質問

How much ventilation does a house need?

After ASHRAE 62.2, 0.03 cfm per square foot plus 7.5 cfm per occupant, with occupants counted as bedrooms plus one. A 2,000 ft² house with three bedrooms needs 90 cfm all the time.

What size bathroom fan do I need?

At least 50 cfm (25 L/s) for a fan switched on when the room is used, or 20 cfm (10 L/s) for one that runs all the time.

How strong should a range hood be?

The standard asks for at least 100 cfm (50 L/s) for a hood vented outside.

Is 0.5 air changes per hour enough?

It is the value the European heat load method assumes for living rooms. Whether it meets the rules depends on the country; the calculator shows both the ASHRAE rate and the air changes it gives.

このテーマのガイド

出典

  1. [1]2016 Update for ASHRAE 62.2 (D. Prather, 2016-11-02). ACCA HVAC Blog. Whole-dwelling ventilation rate of ANSI/ASHRAE 62.2-2016: Qtot = 0.03 × Afloor + 7.5 × (Nbr + 1), in cfm, with Afloor in ft² and Nbr the number of bedrooms.. 確認日: 2026年11月11日
  2. [2]BSC-01-2013 Ventilation Rates (J. Lstiburek, Building Science Symposium 2013). Building Science Corporation. ASHRAE 62.2 rate described as 7.5 cfm per person plus 0.03 cfm per ft² of conditioned area; occupancy is the number of bedrooms plus one.. 確認日: 2026年11月11日
  3. [3]ANSI/ASHRAE Addendum e to ANSI/ASHRAE Standard 62.2-2022, Tables 5-1 and 5-2. ASHRAE. Local exhaust. Demand controlled: vented range hood 100 cfm (50 L/s) for enclosed and open kitchens; bathroom or toilet room 50 cfm (25 L/s). Continuous: enclosed kitchen 5 air changes per hour of the kitchen volume; bathroom or toilet room 20 cfm (10 L/s). No continuous rate is listed for an open kitchen.. 確認日: 2026年11月11日
  4. [4]Heizlast-Berechnung nach DIN EN 12831, Teil 1 (E. Held, SBZ Monteur 01/2005). SBZ Monteur. Minimum air change of 0.5 per hour for living rooms in the European heat load method, shown for comparison.. 確認日: 2026年11月11日

計算式と出典の最終確認日: 2026年11月11日。 計算方法